Isikhungo Sedatha
-
I-IDC Rack (Irekhi Yesikhungo Sedatha Ye-inthanethi)
Izici Eziyinhloko Nemininingwane:
Usayizi: ububanzi obujwayelekile: 19 amayintshi (482.6 mm) Ubude: Iyunithi yeRakhi 47U Ukujula: 1100mm
Sekela usayizi wangokwezifiso ngokwezidingo zakho.
Amandla okulayisha: Kukalwe ngamakhilogremu noma amaphawundi. Kubalulekile ukuqinisekisa ukuthi ikhabhinethi ingakwazi ukusekela isisindo esiphelele sayo yonke imishini efakiwe.
Impahla Yokwakha: Yenziwe ngensimbi esindayo, egoqekayo ebandayo ukuze iqine futhi iqine.
Ukubhobozwa: Izicabha zangaphambili nezangemuva zivame ukubhobozwa (ama-meshed) ukuze kuvunyelwe ukugeleza komoya okuhle kakhulu.
Ukuhambisana: Idizayinelwe ukubamba okokusebenza kwe-rack-mount okujwayelekile okungu-19-intshi.
Ukuphathwa Kwekhebula: Izintambo zokufaka ezimbili ezinamapulaki e-CEE 63A, amabha okuphatha amakhebula / amapayipi omunwe ukuze ahlele futhi aqondise izintambo zenethiwekhi namandla.
Ukupholisa Okuphumelelayo: Iminyango namaphaneli anezimbobo kusiza ukugeleza komoya okufanele, okuvumela umoya obandayo opholile ovela kusistimu yokupholisa yesikhungo sedatha ukuthi ugeleze ezintweni zokusebenza futhi ukhiphe umoya oshisayo ngempumelelo, uvimbela ukushisa ngokweqile.
I-PDU Emile (Iyunithi Yokusabalalisa Amandla): Izimbobo ezimbili ze-36 ze-C39 ezihlakaniphile ze-PDU ezibekwe kumareyili aqondile ukuze zinikeze izindawo zokuphuma kwamandla eziseduze nezisetshenziswa.
Isicelo: IKhabhinethi ye-IDC, eyaziwa nangokuthi ”I-Server Rack” noma “IKhabhinethi Yenethiwekhi”, iwuhlaka olujwayelekile, oluvalekile oluklanyelwe ukubeka ngokuvikelekile nokuhlela imishini ye-IT ebalulekile ngaphakathi kweSikhungo Sedatha noma igumbi leseva elizinikele. "IDC" imele "Isikhungo Sedatha Ye-inthanethi".
-
I-Miner Rack enamachweba angu-40 C19 PDU
Imininingwane:
1. Usayizi weKhabhinethi(W*H*D):1020*2280*560mm
2. Usayizi we-PDU(W*H*D):120*2280*120mm
I-Voltage Yokufaka: izigaba ezintathu 346~480V
Okokufaka kwamanje: 3*250A
I-voltage yokuphumayo: isigaba esisodwa 200 ~ 277V
I-Outlet: Amachweba angama-40 we-C19 Sockets ahlelwe ngezigaba ezintathu
Imbobo ngayinye ine-1P 20A ye-circuit breake
Imishini yethu yezimayini ifaka i-C19 PDU ebekwe mpo eceleni ukuze kube nesakhiwo esihle, esilondoloza isikhala nesochwepheshe.
Ihlanzekile, ihlelekile futhi ilungiselelwe ukusebenza okuphezulu.
-
2500A Ikhabhinethi Yokusabalalisa Amandla Kwangaphandle
Ukucaciswa kwe-switchboard:
1. Amandla kagesi: 415V/240 VAC
2. Okwamanje: 2500A, 3 Isigaba, 50/60 Hz
3. SCCR: 65KAIC
4. Impahla yeKhabhinethi: SGCC
5. Indawo ebiyelwe: NEMA 3R ngaphandle
6. I-MCCB Eyinhloko: Noark 3P/2500A 1PCS
7. MCCB: Noark 3P/250A 10PCS&3P/125A 1PCS
8. 3 Phase muti-function imitha yamandla
-
I-HPC 36 PORTS C39 SMART PDU
Imininingwane ye-PDU
I-1.I-voltage yokufaka: 346-415VAC
2. Okokufaka kwamanje: 3 x 60A
3. I-voltage yokuphuma: 200 ~ 240VAC
4. Izitolo: Izimbobo ezingama-36 zamasokhethi e-C39 anezici zokuzikhiya Isokhethi elihambisana nakho kokubili i-C13 ne-C19
5. Izitolo zihlelwe ngokulandelana kwesigaba ngombala omnyama, obomvu, noluhlaza okwesibhakabhaka
6. Ukuvikelwa: ama-pcs angu-12 we-1P 20A UL489 ama-hydraulic magnetic circuit breaker I-breaker eyodwa njalo ezindaweni ezintathu
7. Ukuqapha okukude kwe-PDU yamanje, i-voltage, amandla, i-KWH
8. Ukuqapha okukude kwembobo ngayinye yokuphumayo yamanje, i-voltage, amandla, i-KWH
9. I-Smart Meter ene-Ethernet/RS485 interface, isekela i-HTTP/SNMP/SSH2/MODBUS
10. Isibonisi se-LCD esisebhodini esinolawulo lwemenyu nokuqapha kwendawo
11. Izinga lokushisa lendawo yokusebenza 0~60C
12. I-UL/CUL Ifakwe ohlwini futhi Yaqinisekiswa (ETL Mark)
13. Itheminali yokufaka inomugqa ongu-5 X 6 AWG ongu-3 wamamitha
-
I-HPC 24 PORTS C39 SMART PDU
Imininingwane ye-PDU:
1. I-voltage yokufaka: 346-415V
2. Okokufaka kwamanje: 3*125A
3. I-voltage yokuphuma: 200-240V
4. Izitolo: Izimbobo ezingama-24 zamasokhethi e-C39 anezici zokuzikhiya Isokhethi elihambisana nakho kokubili i-C13 ne-C19
5. Ukuvikelwa: 24pcs we-1P20A UL489 ama-circuit breaker I-breaker eyodwa kuyo yonke indawo
7. Okokufaka kwe-PDU yokuqapha okukude kanye nembobo ngayinye yamanje, i-voltage, amandla, i-KWH
8. Ukuqapha okukude kwembobo ngayinye yokuphumayo yamanje, i-voltage, amandla, i-KWH
9. I-Smart Meter ene-Ethernet/RS485 interface, isekela i-HTTP/SNMP/SSH2/MODBUS
10. I-UL/CUL Ifakwe ohlwini futhi Yaqinisekiswa